Experimental Lab: Bandwith & Signal Analysis



Intro: In performing this experiment we were able to observe how circuits could be modified in order to resonate within a certain range. We began by solving for theoretical values on the circuit for a radio tuner, which is simply a basic RLC circuit. We needed to first solve for the theoretical bandwidth, and then find the actual bandwidth from the experiment.




Experiment Set up



Theoretical Diagram:

This is the circuit including a 10 Ohm resistor and a 1mF capacitor. The resulting resonance frequency was very large because of the small inductance and capacitance values. 


We solved the bandwith to be 723 Hz theoretically, and that the threshold of deviation could be 3393 plus 381 Hz or minus 342 Hz. Our percent error was determined to be 96.818 percent.{(1423-723)/723*100)}







The same circuit but with a 100 mF capacitor and 100 Ohm resistor.

We found the resonant frequency in this case to be smaller than the previous one, due to the higher values of capacitance. The theoretical bandwidth was 7230 Hz and the threshold was 339-323 Hz, or 339+6910 Hz.

The percent error was much lower this time, 11.61 percent. {(8070-7230)/7230 * 100)}





Conclusion:
An ammeter was used in order to measure the current and we also increased the frequency to the point that the current decreased by 1/sqrt(2), which was the current for half of the power. Our actual values were significantly off in the experiment because of the cheap capacitors and inductors affecting the measured values. The small resistance value is what most definitely threw off the percent error, while in the second round the larger values proved to correct the percent error deviation greatly. By performing this lab we were able to get a good understanding of how circuits that are frequency dependent can be modified such that they obtain specific bandwidth.





Experimental Laboratory: Low Pass and High Pass Filters

Introduction:
 Signal modification is a crucial component to many solutions to real world problems for engineers. In this experiment, we will be working with high pass and pow pass analog filters to form a deeper understanding on how frequencies are amplified or reduced. There will also be data and error analysis.

Intro:
As engineers practice, signal modification is very important for solving real world problems. We worked with both High pass and Low pass filters that were analog. These would give us a better knowledge of the amplification and vice versa of frequencies.

In order to perform the experiment, we set a capacitor box to 0.1mF, and used a 1k Ohm resistor, a frequency generator, DMM, and leads.


Set up for the Low pass frequency response:














Theoretical diagram

















Setup:





Resulting Values:
Theoretical Diagram: High pass filter respose


















Resulting Data:







The resulting data points were graphed in excel and the RMS input voltage from the generator was 5 Volts. We calculated the gain by taking the voltage taken from the measurements and divided it by 5 Rms. The plot is Frequency vs. Gain.
Note: - The maximum for the High pass filter is around 2-3,000 Hz, which should be the expected normal frequency range.















The peak frequency for the low pass filter is around 10-100 Hz, which are independent of the high frequency drop off's.


Note: -As the frequency increased, the input Voltage had to be larger in order to have a constant Vrms, so they are proportionate.


Conclusion: By performing this lab we were able to show that specific frequencies within circuit elements can and will allow certain voltages, while excluding others. The most obvious practical use for this would be radio broadcast waves. The percent error margin was approximately 2.5 percent, which is acceptable.

Wednesday, May 21, 2014

Experimental Lab: AC circuit capacitor


For the lab, the professor hooked up the circuit into the oscilloscope and projected it onto the screen for the whole class. With this we can visualize the behavior of AC voltage inside a capacitor.


Sinusoidal wave going to the capacitor:




The sinusoidal wave changes when frequency changes:




For the graph and data set shown below, our AC voltage supply was attached to a capacitor. We found the capacitor to have a value of 3.3 micro farads.

Complex Numbers in Freemat

For this lab Professor Mason was able to show us how to do complex number calculations by using freemat.





2nd Order Systems

We worked in large groups on the online tutorial for 2nd order circuits.














Monday, April 28, 2014

Experimental Lab - Capacitor Charging and Discharging



By performing this lab we wanted to show the charging and discharging pattern of a capacitor.


Expression for a non ideal capacitor circuit that charges and discharges:

We calculated the components for an ideal capacitor so as to meet our lab's parameters, and had 2.5 mJ of energy into the capacitor.



The box of variable resistance has a maximum output of 1 watt, which was sufficient.














The charging graph was unattainable because of the setting on the oscilloscope that was on a continuous recording. We were able to use a stopwatch and voltmeter in order to measure the charging capacitor's voltage in 20 seconds. We used a voltmeter, stopwatch, oscilloscope, 2 variable resistors, cables, and one capacitor rated at 33 micro farads, shown in the diagram below.









With our set up, the the charging time was 20 seconds and our voltage was 11 V. The discharge was two seconds long, which is a good time.





Calculation of Leakage Resistance and Percent error:


Graphs representing charging and discharging, respectively. This is if the oscilloscope was read once and not twice.



'
-We were able to successfully prove the validity of our theoretical equations for the charging and discharging of the capacitor. We found the leakage resistance around ten times that of the charging resistance, since the leakage resistor is in parallel to the capacitor, which stores energy.


Wednesday, April 16, 2014

"Experimental Lab" - Integrating and deriving Operational amplifiers



Our objective in the in-class lab was to be able to sketch waveforms for the input and output for 1,000 Hz sine, triangle, and square wave inputs. We wanted to be able to explain why a 10M resistor was used, and what would happen if we were to remove this resistor.

 Sine Wave:



Square Wave:




Cosine Wave:






Conclusion and notable facts:

- It was evident that the 10M resistor was important in order to refine the measurements of the DC voltage. If we decided to remove the resistor, the resulting graphs for the output waves would not be like smooth sine function waves.

-Although we can use capacitors to make integrator operational amplifiers which result in a large increase in voltage, but the capacitor's voltage is on a set time. If the capacitor is cheap, the resulting output can not be considered accurate. It is a double edged sword.

Tuesday, April 15, 2014

Experimental Lab: Practical Signal Conditioning



For this experimental lab we needed to perform both level shifting and scaling processes for an op amp, so in order to convert the temperature reliant voltage in celsisus, which came from the LM35 into a voltage amount that was proportional to farenheit.

Initially we tested the LM35 by applying 9 V into it and seeing what the resulting output voltage was. We got 220mA as our result, which is equivalent to room temperature and close enough.













Since our LM35 was fully functioning, we proceeded to solve the output voltage of the op amp according to the schematic below:












Applying the temperature change equation for celsius to farenheit allowed us to solve for the equation in respect to voltage:



We calculated the circuit and knew their to be a relationship between the output and input voltage. This relationship is shown below. We then solved for the reference voltage and removed the resistors that had the correct proportions to our calculated value.
Materials used in the bottom photos are: 3 variable power supplies, various wires, Lm35 temperature sensor, a breadboard, op amp, and potentiometers.




Finished circuit:



output Voltage-

We calculated the percent error shown below, which was 9.2 percent. We used the value of .716 mA because it was from the output of LM35's voltage into farenheit.



We were able to prove that there are practical uses of op amps, that is; to multiply and add. We ultimately had an error of 9.2 percent, but this was due to the inaccurate ratios for the resistors that were rounded off and their actual natural tendency for error.